Add to Cart
ANTMINER S19 Pro+ Hyd 198TH/s with ANTSPACE HK3 and DWT-T/DWT-C Dry-Wet Towers Liquid Cooling Suit
Product Glance | Value | ||
Version Crypto Algorithm | S19 Pro+ Hyd. SHA256 | ||
Hashrate, TH/s | 198 ±3% | ||
Power on wall @35°C, Watt(1-1) | 5445 ±5% | ||
Power efficiency on wall @35°C, J/TH(1-1) | 27.5 ±5% | ||
Detailed Characteristics | Value | ||
Power Supply | |||
Power supply AC Input voltage, Volt(2-1) | 342~418 | ||
Power supply AC Input Frequency Range, Hz | 47~63 | ||
Power supply AC Input current, Amp(2-2) | 30 | ||
Hardware Configuration | |||
Networking connection mode | RJ45 Ethernet 10/100M | ||
Miner Size (Length*Width*Height, w/o package), mm | 410*196*209 | ||
Miner Size (Length*Width*Height, with package), mm | 570*316*430 | ||
Net weight, kg | 15.20 | ||
Gross weight, kg | 17.50 | ||
Environment Requirements | |||
Operation temperature,°C(2-3) | 0~40 | ||
Inlet water temperature,°C | 20-40 | ||
Water flow L/min | 8±10% | ||
Water pressure bar | ≤3.5 | ||
Storage temperature, °C | -20~70 | ||
Operation humidity(non-condensing) , RH | 10~90% |
Specification of ANTSPACE HK3 Mining Container
Product Overview | Value | |||
Version | ANTSPACE HK3 | |||
Dimensions (L*W*H) (mm) | 6058*2438*2896 | |||
Miner Capacity | 210 units -S19 Hyd. Series miner | |||
Container Certification | China Classification Society Certification | |||
Safety Certification | North America/Standards:NFPA 79:2021,UL 508A:2018 R8.21, CSA C22.2 No. 14-18,ANSI/ISO 12100:2012 | |||
Operating Power(kW) | 1047~1050 | |||
PUE(Power Usage Effectiveness) | 1.022(Excluding cooling tower)/1.036(Including cooling tower) | |||
Input Voltage and Frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU,Middle East) | |||
Detailed Characteristics | Value | |||
Shipping Weight(T) | 8 | |||
Operating Weight (T) | 12 | |||
Main Switch of Power Distribution Cabinets(A) | 1200(North America) 1250(EU,Middle East) | |||
Rated Current(A) | 952 | |||
Standard Power(kW) | 1049 | |||
Maximum Power(kW) | 1050 | |||
Rated Current per Miner(A) | 10 | |||
Inlet Cable | The inlet cables can withstand high-voltage of above 600V, with the following requirements per phase: L1 single core cable 600kcMil(300mm²)x4 L2 single core cable 600kcMil(300mm²)x4 L3 single core cable 600kcMil(300mm²)x4 N Single-core cable 600kcMil(300mm²)x4 PE single-core cable 500kcMil(240mm²)x2 | |||
Connection Interface(Cooling Tower) | DN125(GB/T 9119-2010 PN16 DN125) | |||
Connection Interface(Plate Heat Exchage Interface) | DN100(GB/T 9119-2010 PN16 DN100) | |||
Flow Rate(m³/h) | >85 | |||
Quantity of ANTSPACE powered by one 2500kVA Transformer | 2 |
Specification for Dry-Wet Towers DWT-T and DWT-C
Product Overview | Value | |||
Type | Dry-Wet Tower Traditional Type (DWT-T) | Dry-Wet Tower Container Type (DWT-C) | ||
Dimensions(L*W*H)(mm) | 5800*2240*4200 | 6058*2438*2896 | ||
Heat Dissipation Capacity(kW) | 1000 | 1000 | ||
Outlet Temperature @ 28℃ Wet Bulb Temperature | 35℃ | 35℃ | ||
Container Certification | None | China Classification Society Certification | ||
Safety Certification | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, CSA C22.2 No. 14-18, ANSI/ISO 12100:2012 EU Standards: EN ISO 12100, EN 60204-1 | North America/Standards: NFPA 79:2021, UL 508A:2018 R8.21, CSA C22.2 No. 14-18, ANSI/ISO 12100:2012 EU Standards: EN ISO 12100, EN 60204-1 | ||
Operating Power(kW) | 14~28 | 14~28 | ||
Motor Rated Voltage and Frequency | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU,Middle East) | 415V±5% 60Hz(North America) 400V±5% 50Hz(EU,Middle East) | ||
Detailed Characteristics | Value | |||
Shipping Weight(T) | 5 | 6 | ||
Operating Weight(T) | 9 | 10 | ||
Connection Interface(Container) | DN125(GB/T 9119-2010 PN16 DN125) | DN125(GB/T 9119-2010 PN16 DN125) | ||
Water Resupply Pipe Interface | DN40(Internal thread) | DN40(Internal thread) | ||
Drain Pipe Interface | DN65(Internal thread) | DN65(Internal thread) | ||
Noise Level @25℃, 16m | 70dBA | 70dBA | ||
Water Consumption(m³/h) | 1~1.5 | 1~1.5 |